1 3

MEZZANINE

€831,60
Height from floor to ceiling (HT): 225-250 cm
Hopper dimensions (AxB): 70 x 100 cm
Slab thickness (S): Until 26.9 cm
Dimension guide

Mezzanine is the mezzanine loft ladder that guarantees safe and convenient access to the mezzanine floor.

The telescopic handrail on the right side offers extra support when getting on and off, ensuring comfortable access. Two landing handles made of high-quality round tubing ensure a secure hold.

With a certified poplar plywood hatch with low formaldehyde emissions, we also guarantee your health and the safety of the environment.

Certified according to UNI EN 14975:2007 regulations and tested with a static test load of 260 kg, this ladder offers reliable performance.

Product information

  • Free shipping
  • Shipping time: about 3 weeks from order date

Discover more.

  • 11 sturdy and safe steps and mobile structure in 15/10 galvanized sheet metal with shock-absorbing and return springs to facilitate opening and closing
  • Telescopic handrail on the right side to facilitate getting on and off
  • Two round tubular landing handles (diameter 30 mm) 1 meter high
  • Hatch with first choice poplar plywood panel (15 mm thick), certified with low formaldehyde emissions (Class E1 according to UNI EN 13986:2005)

Certifications and Load Capacity:

  • Certified according to UNI EN 14975:2007
  • Load capacity up to 150 kg, tested with a static test load of 260 kg

Ready to Use:

  • Shipped fully assembled and ready for installation.

Step section

15/10 pressed steel sheet protected by electrolytic galvanization.

 

 

Fixing

Anchor plate measuring 6x210x700 [mm] in galvanized steel to be firmly fixed to the floor: 6 holes Ø 8mm.

 

 

Hatch panel

First choice poplar plywood, 15 mm thick.

Second handrail: extra handrail to be installed on the staircase to make going up and down even safer and easier

 


Closing hatch panel in 16mm MDF, certified with minimal formaldehyde emission. Class E1 according to UNI EN 12460-5:2016.

 

The single ladder, fully assembled and ready to be installed, is shipped on a euro pallet measuring 80 x 120 x 50 size (cm) and weighing approximately 50 kg.

Recently viewed

FAQ

How much space must be left free around the hole for installing the loft ladder?

The lower part of the hole must be at least 3 cm away from any perimeter walls for correct installation. The minimum dimensions of the hole vary depending on the model chosen.

Can I adjust the height of the ladder?

Modifying or intervening on the ladder and its components is never permitted. The internal height of the compartment will be provided during the ordering phase, in order to avoid risks or damage to people orobjects. We strongly advise against making changes to the step section, as it is essential to know the internal dimensions of the compartment before placing the order.

Can I install loft ladders in work environments?

Loft ladders are designed for residential use. The exception is represented by the Rigid loft Ladder, which allows specialized personnel for lifts and machinery to access for inspections, checks and maintenance of the technical rooms. However, we recommend respecting the Ispels regulations by making the hole with dimensions of at least 80x120 cm.

Can I fix the ladder to the attic?

It is strictly forbidden to use concrete or drill holes in the frame. For correct installation of the ladder, once positioned perfectly leveled, it is necessary to proceed with the mechanical fixing using the four brackets supplied in the original packaging and the application of polyurethane foam along the perimeter between the floor and the frame. This procedure will also ensure adequate thermal insulation.

When can the loft ladder be installed?

The installation of the loft ladder is only possible after completing all the works, in particular the flooring. It is advisable to avoid using the ladder to finish work on the upper or lower floor.

Can I install the ladder outside?

Loft ladders are designed for indoor use. The exception is the Terrace version, which is equipped with a galvanized upper roof that allows access to an outdoor terrace. All other ladders are not suitable for outdoor installation or use.

What is the correct procedure for installing the climbing support?

The ladder will be removed from the original packaging and fixed on the hole, with the pantograph fully extended. At this point, we recommend that you refer to the instructions supplied with the product, which clarify in detail the anchoring points of the climbing support. The only exception concerns the automatic versions, in which the support, if provided, is installed directly in our factory at the time of purchase.

What is meant by "ceiling height"?

The ceiling height is the measurement in centimeters that must be taken vertically from the lower floor to the sub-floor, excluding the thickness of the floor itself. This measurement is essential for the following versions: Pantograph loft Ladder, Rigid loft Ladder, Terrace loft Ladder, automatic loft Ladder. The ceiling height must be communicated at the time of order, in order to avoid possible risks to people or objects. It is recommended to check, following the instructions in the technical manuals, the spaces necessary during maneuvers and on the floor to avoid any unwanted collisions.

What is meant by "height to floor level"?

The height at floor level is the measurement in centimeters that must be taken vertically from the lower floor to the upper floor. This measurement is essential for the following versions: Wall Pantograph loft Ladder, Motorized Wall loft Ladder. The height at floor level must be communicated at the time of order, in order to avoid possible risks to people or objects. It is recommended to check, following the instructions in the technical manuals, the spaces necessary during maneuvers and on the floor to avoid any unwanted collisions.

Is expert assistance required for installation?

All loft ladders are supplied fully assembled and ready for installation. It will be sufficient to have the hole prepared to accommodate the chosen ladder. Once positioned in the hole, the loft ladder can be used in complete safety. We strongly recommend that you consult the attached manual and scrupulously follow the relevant safety regulations. The help of a second person makes the installation easier and safer.

How should the hole to insert the ladder be configured?

The hole must be positioned at a distance of at least 3 cm from the perimeter walls to allow easy installation. It is important that the hole is made with the sides perpendicular to each other, in order to guarantee a correct position. The upper part of the hole must have the four free corners, essential for installing the "L" shaped brackets that will support the ladder on the wall.

Can I install the Mezzanine ladder on a wooden beam?

Absolutely yes, it will be possible to fix the fixed support included with the ladder on the chosen beam and, using dowels (not supplied), you can anchor the mezzanine ladder to it.

What is the maximum height I can reach?

With the Manual Pantograph version or the automatic version of the ladder, the maximum height that can be reached is 350 cm. With the Rigid version of the ladder, the maximum height that can be reached is 442 cm.